Upgrading a legacy protocol to DNP3 and IP

A cost effective solution for upgrading an existing legacy Radtel protocol network to DNP3 and IP network

All around Australia organisations face the same issues of ageing SCADA and Telemetry systems and the need to plan for their ultimate replacement. Automation Group has helped many organisations to plan for a gradual migration from existing Radtel protocol networks to DNP3 and IP networks.
Brodersen RTU32 Series
• Allows rapid replacement of older legacy RTUs with modern ‘future-proof’ Brodersen RTUs
• Runs on all Brodersen RTU32 Series hardware (no cost option)
• All program code used for the protocol emulation is accessible for diagnostics/modification by end users/integrators
• Allows for staged upgrades of systems i.e. maintain old protocols and comms technologies in parallel with new deployments and upgrades
• Brodersen RTUs include a range of IP functionality such as inbuilt web server, SNMP, SNTP, FTP and VPN security
• Advanced RTU security features include DNP Secure Authentication (master and slave implementations)
• Open programming interface using IEC61131-3 logic with a range of program languages – including the ability to translate from one language to another e.g. convert a program developed in structured text to ladder diagram

Overview
Radtel have been supplying RTU hardware and systems solutions for a range of SCADA and telemetry applications for many years. In recent years the Radtel business has transformed from a provider of turn-key, proprietary solutions to an engineering focused provider of open solutions that use latest technologies and industry standard products. This transformation ensures that end users of Radtel solutions are now offered a range of field sensors, RTUs, communications interfaces and SCADA host software from a growing list of preferred product vendors that Radtel engage with.

Vendor independence sounds wonderful – but are there any traps to be aware of? What if the vendor of the RTU offered to provide emulation of the legacy Radtel protocol had created the solution as an embedded driver (an extension of the product firmware)? Have you ‘jumped from the pan and into the fire’ and simply upgraded to another proprietary solution? If you want true vendor independence then turn the page and read more about the Brodersen RTU32 Series that includes a modern programming environment with an ‘exposed’ Radtel protocol interface that you, or any capable integrator can manage.

Radtel Protocol Implementation Technical Overview
The Radtel protocol is implemented as a user configurable WorkSuite application, allowing a Brodersen RTU to emulate a Radtel RTU and communicate with RadtelSCADA or ClearSCADA master stations. Features include:
• Reply to poll requests
• Output commands for digital and analog data stores
• Change of state reporting for digital signals
• Counting and integration of digital inputs
• Configurable debounce for digital inputs
• Configurable station number and master addresses
• Configurable hardware flow control settings (baud rate, transmit hold on, transmit hold off)
• Configurable comms settings (retry wait period, number of retries)
• Ability to map physical IO and internal variables to Radtel sub-blocks

Easily map IO points to Radtel

Easily map IO points to Radtel

Each Radtel IO point is accessible within a structured data type allowing easy setup and monitoring of sub blocks

Each Radtel IO point is accessible within a structured data type allowing easy setup and monitoring of sub blocks

Input RTU address and comm port settings via a function block

The program code used to create the legacy protocol function block can be monitored and edited online if required

The program code used to create the legacy protocol function
block can be monitored and edited online if required